Application of graphene oxide modified with 8-hydroxyquinoline for the adsorption of Cr (VI) from wastewater: Optimization, kinetic, thermodynamic and equilibrium studies

Sheikhmohammadi, Amir and Mohseni, Seyed Mohsen and khodadadi, Rouhollah and Sardar, Mahdieh and Abtahi, Mehrnoosh Abtahi and Mahdavi, Sakineh and Keramati, Hassan and Dahaghin, Zohreh and Rezaei, Soheila and Almasian, Mohammad and Sarkhosh, Maryam and Faraji, Majid and Nazari, Shahram (2017) Application of graphene oxide modified with 8-hydroxyquinoline for the adsorption of Cr (VI) from wastewater: Optimization, kinetic, thermodynamic and equilibrium studies. Journal of Molecular Liquids, 233. pp. 75-88.

[img]
Preview
Text
Sakineh Mahdavi.pdf

Download (1MB) | Preview

Abstract

In the present study, removal of Cr (VI) from aqueous solution was investigated by adsorption onto graphene oxide modified with 8-hydroxyquinoline (8-HQ- GO-Fe3O4). Graphen oxide (GO) sheets, magnetic GO -Fe3O4 nanocomposite and the 8-HQ- functionalizedGO-Fe3O4 nanocomposite (8- HQ- GO-Fe3O4)were freshly synthesized and characterized by Scanning electron microscope (SEM) images, Fourier transform infrared (FTIR) spectroscopy, energy dispersive X-ray (EDAX) and thermogravimetric (TGA) analysis. The response surface methodology using R software was chosen to investigate the composition effect of input independent factors (pH, 8-HQ/GO dose, time and Cr (VI) concentration) and one dependent output response (removal efficiency). The lower P-value (1.33 × 10−15), higher F-value (240.4), higher R2 (multiple R-squared: 0.994, adjusted Rsquared: 0.989) and insignificant lack of fit (0.38) indicate that reduced full second-order model has highly significant for adsorption of Cr (VI) by 8-HQ- GO-Fe3O4 and it also is represented satisfactory adjustment between model and experimental data. The predicted optimal conditions by model (to involve all parameters simultaneously) for the maximum removal efficiency (95.77%) were achieved (pH, 6.58; 8-HQ/GO dosage, 98.4 g L−1; contact time, 178.4 min and Cr (VI) concentration, 1 mg L−1). Based on reported results, a high correlation coefficient (R2) was found for the Langmuir model compared with the Freundlich and the Temkin models that confirm the reasonably fit to the data. The maximum adsorption capacity calculated from the Langmuir was 11.9 mg g−1 at 308 K. The kinetics followed is pseudo second order in nature and the intraparticle diffusion was the dominating mechanism. The thermodynamic data revealed the endothermic nature, an increase in the degree of freedom of the adsorbed ions and spontaneous sorption for the adsorption process. Also the Ea value found to be 1.39 kJ mol−1 indicating chemical sorption.

Item Type: Article
Subjects: R Medicine > R Medicine (General)
Depositing User: samira sepahvandy
Date Deposited: 23 Oct 2017 12:10
Last Modified: 23 Oct 2017 12:10
URI: http://eprints.lums.ac.ir/id/eprint/806

Actions (login required)

View Item View Item