Pre-aspiration outpatient ultrasound can accurately predict dry taps in prosthetic hips suspected of infection; a prospective study

Mirzaei, Alireza and Shafiei, Seyyed Hossein and Sadeghi-Naini, Mohsen and Rikhtehgar, Masih and Abolghasemian, Mansour Pre-aspiration outpatient ultrasound can accurately predict dry taps in prosthetic hips suspected of infection; a prospective study.

[img] Text
52c.pdf

Download (234kB)

Abstract

Introduction: Aspiration represents the most potent method for exploring the potential occurrence of Periprosthetic Joint Infection (PJI). However, dry taps are common. While aspiration under ultrasound (US) guidance in the radiology department has become increasingly popular, hip aspiration is still routinely conducted in the operating room (OR) under x-ray guidance in numerous medical centers. When conducted within the confines of the OR, a dry tap aspiration not only subjects the patient to an unnecessary invasive procedure but also constitutes a substantial strain on OR time and resources. Our objective was to assess whether an outpatient US conducted before aspiration could reliably predict the likelihood of encountering a dry hip aspiration. Methods: In a prospective study, we enrolled 50 hips who were suspected of PJI and slated for revision total hip arthroplasty and required hip aspiration. Before the aspiration procedure, we conducted an outpatient hip ultrasound (US) to assess the presence of fluid collection. Subsequently, all patients underwent aspiration under fluoroscopy in the OR, irrespective of the ultrasound findings We then assessed the level of agreement between the ultrasound results and the outcomes of hip aspiration. Results: The US exhibited a sensitivity of 95.7% (95% CI 69.8-91.8), a specificity of 74.1% (95% CI 52.8-91.8), a positive predictive value of 75.9% (95% CI 50.9-91.3), and a negative predictive value of 95.2% (95% CI 71.3-99.8) in predicting the success of aspiration. Discussion: Pre-aspiration outpatient US demonstrates a high degree of accuracy in predicting dry taps in these patients. We recommend its incorporation into the hip aspiration procedure in medical centers where aspiration is performed in the operating room. In the broader context, these findings reinforce the preference for US-guided aspiration within the radiology department over x-ray-guided aspiration in the operating room since about ¼ of the positive USs for hip collection will lead to a dry tap if the aspiration is performed in the OR under fluoroscopy guidance.

Item Type: Article
Depositing User: lorestan university
Date Deposited: 24 Sep 2024 11:38
Last Modified: 24 Sep 2024 11:38
URI: http://eprints.lums.ac.ir/id/eprint/4887

Actions (login required)

View Item View Item