Diffusion-weighted magnetic resonance imaging at 1.5 T for peripheral zone prostate cancer: the influence of the b-value combination on the diagnostic performance of apparent diffusion coefficient

Rezaeian, Abbas and Ostovari, Mohsen and Hoseini-Ghahfarokhi, Mojtaba and Khanbabaei, Hashem (2022) Diffusion-weighted magnetic resonance imaging at 1.5 T for peripheral zone prostate cancer: the influence of the b-value combination on the diagnostic performance of apparent diffusion coefficient. Pol J Radiol.

[img]
Preview
Text
70f.pdf

Download (125kB) | Preview

Abstract

Purpose: Diffusion-weighted imaging as a noninvasive functional modality plays a valuable role in the evaluation of prostate cancer. However, there is still no agreement on the number and range of b-values to be used. Therefore, the purpose of this study is to investigate the influence of b-value choice on the diagnostic performance of apparent diffusion coefficient (ADC) values for prostate cancer detection. Material and methods: Fifty-nine consecutive patients with abnormal digital rectal examination findings and raised serum prostate-specific antigen were chosen for magnetic resonance imaging of the prostate before systematic 12-core trans-rectal ultrasound-guided prostate biopsies. ADC values for each ROI were calculated from different b-value combinations (0-1600 s/mm2) by a monoexponential model. Mann-Whitney and the paired-sample t-test were used to compare the mean ADC values for malignant lesions and noncancerous tissues. ROC curve analysis was used to evaluate the diagnostic performance of ADC values in distinguishing prostate cancer from normal-tissue ROIs. Results: The differences between mean ADC values of malignant lesions and contralateral healthy tissues were significant for all the pairs of b-value combinations. The pair of b-values 50 and 1200 provided the highest AUC (0.94), with a sensitivity of 90.2%, a specificity of 92.6%, and an accuracy of 91.2% at an ADC cut-off of 1.23 × 10-3 mm2/s. Conclusions: Our study showed that using a 1.5-Tesla MRI scanner the diagnostic performance of ADC values estimated from the b-value pair 50 and 1200 s/mm2 was highest. However, some other b-value pairs provided statically comparable diagnostic performance.

Item Type: Article
Subjects: R Medicine > RC Internal medicine > RC0254 Neoplasms. Tumors. Oncology (including Cancer)
Divisions: Faculty of Medicine, Health and Life Sciences > School of Medicine
Depositing User: lorestan university
Date Deposited: 22 May 2022 09:16
Last Modified: 22 May 2022 09:16
URI: http://eprints.lums.ac.ir/id/eprint/3777

Actions (login required)

View Item View Item