Effect of repeated firing on the translucency of CAD-CAM monolithic glass-ceramics

Nejatidanesh, Farahnaz and Azadbakht, Kamran and Savabi, Omid and Sharifi, Morteza and Shirani, Mohammadjavad (2019) Effect of repeated firing on the translucency of CAD-CAM monolithic glass-ceramics. Journal of Prosthetic Dentistry.

[img]
Preview
Text
effffffect.pdf

Download (462kB) | Preview

Abstract

Statement of problem: The effects of multiple firings on the translucency of newly introduced computer-aided design and computer-aided manufacturing (CAD-CAM) glass-ceramics have not been well evaluated. Purpose: The purpose of this in vitro study was to assess the changes in the translucency of high-translucency (HT) and low-translucency (LT) lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) glass-ceramics of 0.6 and 1 mm thickness during crystallization, correction, and glaze firing cycles. Material and methods: Eighty specimens in 8 groups (n=10) were sectioned and polished to obtain thicknesses of 0.6 and 1 mm. The specimens were then fired in 3 cycles, and the color coordinates were measured by using a spectrophotometer after each cycle. The translucency parameter (TP) and the contrast ratio (CR) were calculated to determine the translucency level. The data were analyzed by using a statistical software program. The TP and CR data after each firing cycle were compared within each group by using repeated-measures ANOVA. Pair-wise comparisons were made by using a multiple paired t test. Comparisons between the 2 thicknesses of different materials were made by using the independent t test (α=.05). Results: Repeated firings significantly increased the translucency of 0.6-mm LT-LDS and decreased the translucency of 0.6-mm HT-ZLS (P<.017). No significant changes were noted in the translucency of specimens of 1-mm thickness after repeated firings. Also, 0.6-mm-thick specimens of all materials had significantly higher translucency than 1-mm-thick specimens (P≤.001). The highest translucency was noted in HT-LDS, followed by HT-ZLS. Conclusions: Repeated firings significantly affected the translucency of LDS and ZLS CAD-CAM glass-ceramics. The translucency increased with decreasing thickness. © 2019 Editorial Council for the Journal of Prosthetic Dentistry

Item Type: Article
Subjects: R Medicine > RK Dentistry
Divisions: Faculty of Medicine, Health and Life Sciences > School of Medicine
Depositing User: samira sepahvandy
Date Deposited: 19 Jan 2020 04:21
Last Modified: 19 Jan 2020 04:21
URI: http://eprints.lums.ac.ir/id/eprint/1902

Actions (login required)

View Item View Item